| Parameter | Value |
|---|---|
| Temp control | |
| Cooling capacity 400 Vac model¹ | 5,5 kW |
| COP cooling 400 Vac¹ | 2,4 |
| Heating capacity electric 400 Vac model | 4,5 kW |
| Voltage for heating capacity electric 400 Vac model | 400 Vac |
| Max airflow indoor (free blowing) | 1050 m³/h |
| Fresh airflow | 60 m³/h |
| Refrigerant | R134A (non-flammable, A1, allowed in EU for mobile applications, cooling batteries and equipment). R1234yf or R513a on request |
| Max ambient temperature | 45 °C |
| Min ambient temperature | -15 °C |
| Max indoor temperature | 40 °C |
| Min indoor temperature | -15 °C |
| Climate control norm or specification | EN 14813-1:2006 |
| Electrical | |
| Primary voltage range 400 Vac model | 400 Vac ±10%, 3-phase, 50–60 Hz ±5% |
| Secondary voltage range | 20–28 Vdc |
| Control system | CANopen, Remote on/off, HMI panel, Modbus RS485, or self-controlled |
| Power consumption secondary voltage | 920 W |
| Degree of protection (components protected from water and dust) | IP20 |
| Mechanical | |
| Size | 963 x 542 x 599 mm (L x W X H) |
| Weight | 160 kg |
| Material | Zinc-plated steel |
| Colour | Powder-coated Ral 7035 |
| Sound level indoor (1 m, non-resonating mounting) | 65 dB(A) |
| Sound level outdoor (1 m, non-resonating mounting) | 71 dB(A) |
| Hazard level (according to EN 45545-2:2020+A1:2023) | HL3 |
| Shock and vibration norm or specification | Designed according to EN 61373 |
¹ Tested in 30 °C 50% RH indoor / 35 °C outdoor. Cooling duty varies on climatic conditions and altitude, consult DC Airco for specific applications.